TFCO201 - Airborne CO2 Concentration Sensor
The TFCO201 sensor measures carbon dioxide (CO2) concentrations in airborne applications. It supports integration with UAVs and can be used with a Pixhawk autopilot system or as a part of the TF-ATMON monitoring system.
This sensor uses the SCD41 CO2 sensor for high-accuracy measurements and includes additional environmental data such as temperature and humidity.
Features
- CO2 measurement range: 400 – 5000 ppm
 - Accuracy: ±(40 ppm + 5 % of reading) for CO2
 - Humidity range: 0% to 100% RH
 - Temperature range: -10°C to 60°C
 - Communication Interface: I2C with address 0x62
 - Power supply: 3.6V to 5.4V
 - Low power consumption: Supports low power periodic measurements
 - Compact size: 30 x 15 x 6.5 mm (PCB only without housing)
 
Applications
- Atmospheric sounding: Ideal for direct measurements in atmospheric research via UAVs.
 - Urban air quality monitoring: Helps locate and map sources of CO2 emissions.
 - Ecosystem change observation: Suitable for tracking CO2 levels in various ecosystems.
 - Industrial emission control: Monitor CO2 emissions from industrial facilities.
 
Sensor Parameters
| Parameter | Value | Notes | 
|---|---|---|
| CO2 Sensor Model | SCD41 | Other supported sensors: SCD40, SCD42 | 
| CO2 Accuracy | ± (40 ppm + 5% of reading) | Measurement range: 400 – 5000 ppm | 
| Humidity Measurement Range | 0% – 100% RH | |
| Temperature Accuracy | ± 1.5 °C | Temperature range: -10 °C to 60 °C | 
| Operating Voltage | 3.6 – 5.4V | Internal overvoltage protection | 
| Interface | I2C (0x62) | Supports I2C address modification | 
| Mass | 3 g | Without cabling | 
| Dimensions | 30 x 15 x 6.5 mm | PCB size | 
| Weather Resistance | IP40 | External connectors fully occupied | 
Usage Instructions
The sensor can be integrated directly with UAV systems. The PX4 autopilot supports it and allows real-time data logging and communication with the ground station. For extended usage scenarios and system setup, refer to the sensor’s GitHub repository.
Installation & Calibration
- I2C Address Setup: Default address is 0x62, which can be translated using the TFI2CADT01 module.
 - Temperature Offset: The sensor supports temperature offset configuration to improve accuracy.
 
Schematics
Datasheet Reference
For more detailed technical specifications of the CO2 sensor used, refer to the Sensirion SCD41 Datasheet.